RWD D165HT CO2 Incubator

RWD D165HT CO2 Incubator

  • Control & Range
    ± 0.1 ℃ @37 ℃, 3 ℃ -55 ℃ Higher Than Ambient Temperature
  • Place of Origin
    China
  • Brand Name
    RWD
  • Model Number
    D165HT

RWD D165HT CO2 Incubator

The RWD D165HT CO₂ incubator for cell culture achieves precise three-gas control by regulating the input of CO₂ or N₂. RWD D165HT CO₂ incubator for cell culture provides a controlled oxygen culture environment for specific cell tissues,better simulating the in vivo cell environment and enhancing cell growth performance.

Advantages

More flexible gas configuration
Optional oxygen control module can simulate the low oxygen environment of cells in the body, promoting the rapid and healthy growth of primary cells, stem cells, and embryonic cells. The oxygen detector uses a durable zirconia sensor to ensure precise and stable control of O2 concentration.


More effective sterilization procedure
The 180°C dry heat sterilization program can efficiently kill fungi,molds,bacteria,and their spores.It has been validated by a third party,ensuring a sterilization effectiveness of up to 12log SAL.The entire process takes approximately 12 hours.


More efficient humidity control
The reservoir design enhances internal space efficiency and accelerates humidity recovery by five times compared to standard water pans.After a 30-second door opening,relative humidity is restored within 10 minutes.The system monitors water levels in real-time to ensure timely refilling and maintain optimal humidity.It also features a low-humidity mode to prevent condensation and contamination.


More energy-efficient internal door accessories
Optinonal triple small-section door design not only effectively reduces the amount of air exchange each time a door is opened,thereby lowering the risk of fluctuations in the internal environment,but also significantly enhances the convenience and safety of operations.


A brand-new software upgrade

The R-Link intelligent cloud-based control system allows you to monitor the device status anytime and receive real-time alarm notifications on your mobile device, ensuring timely handling and safeguarding the samples.



Specifications

Parameters Size & Weight Interior Volume 170L
Internal dimensions 47.0(W)×57.0(D)×60.0(H) cm
External dimensions 69.0(W)×87.0(D)×93.0(H)
Net Weight 110KG
Shelves Number (Standard & Max) 3, up to 11
Dimensions 41.8*46.5cm;1943.7cm2
Load bearing 16 kg/sheet
Temperature Heating Method Gas jacket direct heating
Sensor Dual Pt1000 platinum thermistor
Controller PID
Control & Range ± 0.1 ℃ @37 ℃, 3 ℃ -55 ℃ higher than ambient temperature
Uniformity ±0.25℃@37℃
CO2 Concentration Control & Range ±0.1%@5%,0 ~ 20%
Sensor 190 ℃ high temperature infrared (IR) probe
Input pressure Recommended 0.08~ 0.1 Mpa
Uniformity ±0.3%
Readability & Setability 0.1%
Humidity Moisturizing mode Integrated reservoir
Relative humidity ≥93%
Volume 3.8L
Display Water level display
O2 control Control and scope ± 0.1%, 1% to 21% (hypoxia)
Sensor Zirconia
Input pressure Recommended 0.08~ 0.1 Mpa
Antifouling control Sterilization temperature 180 ℃ high temperature dry heat sterilization
Sterilization time About 12 hours
Filter 0.3 µm HEPA high-efficiency filter
Security settings Temperature alarm setting User customizable, upper limit: (T + 0.1)~ (T + 5.0); lower limit: (T-0.1)~ (T-5.0)
CO2 alarm settings User customizable, upper limit: (T + 0.1%)~ (T + 1.0%); lower limit: (T-0.1%)~ (T-1.0%)
Humidity alarm settings Low water level alarm
Door alarm settings Alarm prompt 2 minutes after opening the door
Safety door lock During high-temperature sterilization, the internal cavity temperature exceeds 65 ℃ and automatically locks
Software settings Display control High definition touch screen
Data storage and export Equipped with R-link IoT module, it can view equipment operation status and receive equipment alarm data through mobile end or fixed end point. The screen can display parameter data within one month and automatically record parameter data within six months. It records once per minute and can also record alarm records and operation records within six months.