RWD 69100 Rotational Digital Stereotaxic's mouse head can be easily rotated flexibility so as to adjust the level of the skull. The accuracy of mediolateral rotation perfectly solves the bleeding problem when you inject through the venous sinus. Alignment Indicator can feedback whether the height of the animal’s head is horizontal. Centering Scope helps find Bregma and Lambda points. And you don’t need to set up Bregma repeatedly.
1. Fitted with a sagittal positioning plate design, To minimize the levelness, inclination and alignment of the skull.
2. Apparatus improves experiment efficiency, and the fixation process in animals is not repeated.
3. More detailed five-dimensional space positioning can meet the needs of other sites.
4. The operation arm has been tested by the motor for 100,000 times, which makes it more durable.
5. With 40X Central Magnifier and Alignment Indicator, the skull flattening speed is faster and the brain area positioning accuracy is higher.
6. Can be combined with inhalation anesthesia machine, animal mortality is low, the risk of surgery is small.
Item | Description |
Tri-axial displacement Range in Sagittal plate (X, Y, Z axis) | 30mm |
left and right rotation Angle adjustment range in Sagittal plate | ±30° |
Swing the Angle up and down to adjust the range in Sagittal plate | ±10° |
horizontal Angle adjustment range in Center floor | ±10° |
Displacement distance of operating arm (X, Y, Z axis) | 80mm |
Plate size | 400mm X 325mm |
The mirror is still served at magnification | 40X |
Alignment Indicator resolution | 0.01mm |
Model | Product Description | Remarks |
69108 | Rotational Digital Stereotaxic for Mouse, SGL.M, 69110, 69113, 69114, 69133, 69137 | Standard configuration, contains 69110 Mouse Anesthesia Adaptor with Tubing, 69113 15° Angle Adaptor, 69114 60°Ear Bars for Mouse, 69133 40X Central Magnifier and 69137 Alignment Indicator. |
69118 | Rotational Digital Stereotaxic for Mouse, Dual M, 69110, 69113, 69114, 69133, 69137 | |
69109 | Rotational Digital Stereotaxic for Rat, SGL.M, 69112, 69113, 69116, 69133, 69137 | Standard configuration, contains 69112 Rat Anesthesia Adaptor with Tubing, 69113 15° Angle Adaptor, 69116 18° EarBars for Rat, 69133 40X Central Magnifier and 69137 Alignment Indicator. |
69119 | Rotational Digital Stereotaxic for Rat, Dual M, 69112, 69113, 69116, 69133, 69137 | |
69136 | Operating Platform for Stereotaxic | |
69110 | Mouse Anesthesia Adaptor with Tubing(<30g) | 69108, 69118 contains. |
69111 | Mouse Anesthesia Adaptor with Tubing(30~70g) | Not included in standard configuration, optional according to experimental needs. |
69112 | Rat Anesthesia Adaptor with Tubing(<300g) | 69109, 69119 contains. |
69114 | 60° Ear bars for Mouse | 69108, 69118 contains. |
69116 | 18° Ear bars for Rat | 69109, 69119 contains. |
69120 | 3-axis Digital Manipulator, Left Hand | 69108, 69118, 69109, 69119 contains. |
69121 | 3-axis Digital Manipulator, Right Hand | 69118, 69119 contains. |
69207 | Attachment for Rotational Digital Stereotaxic Holder |